Zonespot II Highbay emergency light TWS8492WMC

Self-contained ESCAP Emergency Light with 1 h Super Capacitor and Lumi Test self-testing

The Zonespot II Highbay is a surface-mounted emergency light that is particularly suitable for high spaces. The luminaire’s optics are designed to provide a broad, uniform light pattern that illuminates open areas effectively.
Thanks to the IP44 enclosure class, the Zonespot II is also suitable for damp areas. The luminaire is easy and quick to install thanks to a separate mounting base, which is also connected to the power supply.

1 h
icon-ce
EN 60598_2_22
icon-Escap
850 °C
43
icon-LED
icon-LumiTest
220-240 V 50/60 Hz AC
icon-ProtectionClassII
9003
icon-Through-wiring
Product codeTWS8492WMCElectrical number (FI)4148683
GTIN6438045027661TARIC code94056180
Weight0,90 kgMeasurements18,00 × 18,00 × 5,00 cm
Backup (h)1 hBody materialplastic
CE MarkYesColourRAL9003 (Signal white)
Electrical Installation2/3 x 2,5 mm²EN 60598-2-22Yes
EscapYesETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)850 IP ClassIP43
Light SourceLEDLumi TestYes
Luminous Flux (lm)110 Max Input Power VA3 VA
MountingSurfaceMounting optionPendel
Nominal Supply Voltage220-240 V, 50/60 Hz ACProtection ClassII
Temperature Range Min - Max (°C)-25...+35Suitable for Through-WiringYes
Product codeTWS8492WMC
Electrical number (FI)4148683
GTIN6438045027661
TARIC code94056180
Weight0,90 kg
Measurements18,00 × 18,00 × 5,00 cm
Backup (h)1 h
Body materialplastic
CE MarkYes
ColourRAL9003 (Signal white)
Electrical Installation2/3 x 2,5 mm²
EN 60598-2-22Yes
EscapYes
ETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)850
IP ClassIP43
Light SourceLED
Lumi TestYes
Luminous Flux (lm)110
Max Input Power VA3 VA
MountingSurface
Mounting optionPendel
Nominal Supply Voltage220-240 V, 50/60 Hz AC
Protection ClassII
Temperature Range Min - Max (°C)-25...+35
Suitable for Through-WiringYes

Scale Images

Scale image

Light Distribution Charts

Emergency lighting for open areas (ceiling mounting)

  • 0.5 lux table for open areas, in accordance with EN 1838; 0.5-m border zone is taken into account in the table.
  • Level of measurement 0.02 m, measurement result in emergency mode
R1 distance from wall, X axis
R2 mounting distance, X axis
R3 mounting distance, Y axis
R4 distance from wall, Y axis

Emergency lighting for open areas (ceiling mounting)

Mounting height (m)Below the light (lx)R1 (m)R2 (m)R3 (m)R4 (m)
--0.5 lx0.5 lx0.5 lx0.5 lx
2.5272.5552.5
3182.55.55.52.5
4102.55.55.52.5
64.53663
82.536.56.53
101.53773
121.253773

Accessories

Product codeElectrical numberDescription 
TW77507B4281135Shock protecting cover TW77507BAdd to cart

How to contact our sales teams

Teknoware Emergency Lighting distributors and sales offices around the world: