Solid Zone Midbay emergency light TWT3751WK

Addressable 230 V centrally supplied emergency light

Designed for emergency lighting in open areas, Solid Zone Midbay is an emergency light with a IP65 enclosure.
The luminaire is completely dust proof and water proof, so it is suitable for example for industrial premises and parking halls. Centrally supplied luminaires are also suitable for outdoor use.
Special attention has been paid to the design, for easy installation.

icon-ce
EN 1838
EN 60598_2_22
650 °C
icon-IntelligentControl
65
icon-LED
220-240 V 50/60 Hz AC DC
icon-ProtectionClassI
9003
icon-TapsaControl
icon-Through-wiring
Product codeTWT3751WKElectrical number4148726
GTIN6438045028088TARIC code94056180
Weight1,10 kgMeasurements37,10 × 18,10 × 5,70 cm
Body materialplasticCE MarkYes
ColourRAL9003Electrical Installation3 x 2,5 mm²
EN 1838YesEN 60598-2-22Yes
ETIM classEmergency luminaire (EC001957)Glow Wire Test of Plastic Materials (°C)650
Intelligent ControllerYesIP ClassIP65
Light SourceLEDLuminous Flux (lm)1600
Max Input Power VA15,7 VAMax Input Power W14,1 W
MountingSurfaceNominal Supply Voltage220-240 V, 50/60 Hz AC, DC
Protection ClassITapsa ControlYes
Temperature Range Min - Max (°C)-30…+40Suitable for Through-WiringYes
Product codeTWT3751WK
Electrical number4148726
GTIN6438045028088
TARIC code94056180
Weight1,10 kg
Measurements37,10 × 18,10 × 5,70 cm
Body materialplastic
CE MarkYes
ColourRAL9003
Electrical Installation3 x 2,5 mm²
EN 1838Yes
EN 60598-2-22Yes
ETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)650
Intelligent ControllerYes
IP ClassIP65
Light SourceLED
Luminous Flux (lm)1600
Max Input Power VA15,7 VA
Max Input Power W14,1 W
MountingSurface
Nominal Supply Voltage220-240 V, 50/60 Hz AC, DC
Protection ClassI
Tapsa ControlYes
Temperature Range Min - Max (°C)-30…+40
Suitable for Through-WiringYes

Scale Images

Scale image

Light Distribution Charts

Emergency lighting for open areas (ceiling mounting)

  • 0.5 lux table for open areas, in accordance with EN 1838; 0.5-m border zone is taken into account in the table.
  • Level of measurement 0.02 m, measurement result in emergency mode
R1 distance from wall, X axis
R2 mounting distance, X axis
R3 mounting distance, Y axis
R4 distance from wall, Y axis

Emergency lighting for open areas (ceiling mounting)

Mounting height (m)Below the light (lx)R1 (m)R2 (m)R3 (m)R4 (m)
--0.5 lx0.5 lx0.5 lx0.5 lx
360612126
4346.513136.5
6157.515157.5
888.517178.5
1059.519199.5
12410202010
143.510.5212110.5
162.511222211
18211.5232311.5
201.512242412.5