Solid Zone Lowbay emergency light TWS3292WM

Self-contained Escap Emergency light for open areas with 1 h Super Capacitor and Lumi Test Self-testing

Solid Zone Lowbay has been developed for the emergency lighting of open areas.
High enclosure class (IP65) ensures that the luminaire is completely dust proof and water proof.
Solid Zone Lowbay is suitable for example for industrial premises and parking halls. Escap and centrally supplied luminaires are also suitable for outdoor use. The Solid luminaire uses long lasting leds as its light source.
Special attention has been paid to the design, for easy installation.

1 h
icon-ce
EN 1838
EN 60598_2_22
icon-Escap
850 °C
65
icon-LED
icon-LumiTest
220-240 V 50/60 Hz AC
icon-ProtectionClassII
9003
icon-Through-wiring
Product codeTWS3292WMElectrical number4282277
GTIN6438045021102TARIC code94056180
Weight1,50 kgMeasurements37,10 × 18,10 × 5,70 cm
Backup (h)YesBody materialplastic
CE MarkYesColourRAL9003
Electrical Installation2/3 x 2,5 mm²EN 1838Yes
EN 60598-2-22YesEscapYes
ETIM classEmergency luminaire (EC001957)Glow Wire Test of Plastic Materials (°C)850
IP ClassIP65Light SourceLED
Lumi TestYesLuminous Flux (lm)94
Max Input Power VA3 VAMountingSurface
Nominal Supply Voltage220-240 V, 50/60 Hz ACProtection ClassII
Temperature Range Min - Max (°C)-25…+35Suitable for Through-WiringYes
Product codeTWS3292WM
Electrical number4282277
GTIN6438045021102
TARIC code94056180
Weight1,50 kg
Measurements37,10 × 18,10 × 5,70 cm
Backup (h)Yes
Body materialplastic
CE MarkYes
ColourRAL9003
Electrical Installation2/3 x 2,5 mm²
EN 1838Yes
EN 60598-2-22Yes
EscapYes
ETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)850
IP ClassIP65
Light SourceLED
Lumi TestYes
Luminous Flux (lm)94
Max Input Power VA3 VA
MountingSurface
Nominal Supply Voltage220-240 V, 50/60 Hz AC
Protection ClassII
Temperature Range Min - Max (°C)-25…+35
Suitable for Through-WiringYes

Scale Images

Scale image

Light Distribution Charts

Emergency lighting for open areas (ceiling mounting)

  • 0.5 lux table for open areas, in accordance with EN 1838; 0.5-m border zone is taken into account in the table.
  • Level of measurement 0.02 m, measurement result in emergency mode
R1 distance from wall, X axis
R2 mounting distance, X axis
R3 mounting distance, Y axis
R4 distance from wall, Y axis

Emergency lighting for open areas (ceiling mounting)

Mounting height (m)Below the light (lx)R1 (m)R2 (m)R3 (m)R4 (m)
--0.5 lx0.5 lx0.5 lx0.5 lx
2.525995
31.549.59.54