Linespot II Midbay emergency light TWS8892WMT

Self-contained Escap Emergency light with 1 h Super Capacitor and Lumi Test Self-testing

The Linespot II Midbay is a surface-mounted emergency light. The luminaire’s optics are designed to provide a long and narrow light pattern that illuminates corridors and escape routes efficiently.
Thanks to the IP44 enclosure class, the Linespot II is also suitable for damp areas. The luminaire is easy and fast to install, thanks to a separate mounting base, which is also connected to the power supply.

1 h
icon-ce
EN 60598_2_22
icon-Escap
850 °C
43
icon-LED
icon-LumiTest
220-240 V 50/60 Hz AC
icon-ProtectionClassII
9005 (Jet black)
icon-Through-wiring
Product codeTWS8892WMTElectrical number (FI)4148787
GTIN06438045028774TARIC code94056180
Weight0,90 kgMeasurements18,00 × 5,00 × 18,00 cm
Backup (h)YesBody materialplastic
CE MarkYesColourRAL9005 (Jet black)
Electrical Installation2/3 x 2,5 mm²EN 60598-2-22Yes
EscapYesETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)850 IP ClassIP43
Light SourceLEDLumi TestYes
Luminous Flux (lm)80 Max Input Power VA3 VA
MountingSurfaceMounting optionPendel
Nominal Supply Voltage220-240 V, 50/60 Hz ACProtection ClassII
Temperature Range Min - Max (°C)-25...+35Suitable for Through-WiringYes
Product codeTWS8892WMT
Electrical number (FI)4148787
GTIN06438045028774
TARIC code94056180
Weight0,90 kg
Measurements18,00 × 5,00 × 18,00 cm
Backup (h)Yes
Body materialplastic
CE MarkYes
ColourRAL9005 (Jet black)
Electrical Installation2/3 x 2,5 mm²
EN 60598-2-22Yes
EscapYes
ETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)850
IP ClassIP43
Light SourceLED
Lumi TestYes
Luminous Flux (lm)80
Max Input Power VA3 VA
MountingSurface
Mounting optionPendel
Nominal Supply Voltage220-240 V, 50/60 Hz AC
Protection ClassII
Temperature Range Min - Max (°C)-25...+35
Suitable for Through-WiringYes

Scale Images

Scale image

Light Distribution Charts

Emergency lighting for escape routes (ceiling mounting)

  • 1 lux table for the centre line of an escape route, in accordance with EN 1838.
  • Level of measurement 0.02 m, measurement results in emergency mode.
R1 distance from wall, X axis
R2 mounting distance, X axis
R4 distance from wall, Y axis

Emergency lighting for escape routes (ceiling mounting)

Mounting height (m)Below the light (lx)R1 (m)R2 (m)R4 (m)
--1 lx1 lx1 lx
2.5113.581
383.591
44.54101
624111
81.13111

How to contact our sales teams