Zonespot II Lowbay emergency light Y0471W

24-230 V centrally supplied LED emergency light (Invidually packed TWT0471W)

The Zonespot II Lowbay is a small and elegant emergency light, for recess mounting. It is specially designed for illuminating open areas. Zonespot II Lowbay takes advantage of the latest LED technology.

icon-ce
EN 60598_2_22
650 °C
20
icon-LED
24-230 V 50/60 Hz AC DC
icon-ProtectionClassIII
icon-ProtectionClassI
9003
icon-Through-wiring
Product codeY0471WElectrical number (FI)4281551
GTIN6438045017129TARIC code94056180
Weight0,50 kgMeasurements38,50 × 11,50 × 9,50 cm
Body materialplasticCE MarkYes
ColourRAL9003Electrical Installation2 x 2,5 mm² (24 V), 3 x 2,5 mm² (230 V)
EN 60598-2-22YesETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)650 IP ClassIP20
Light SourceLEDLuminous Flux (lm)280
Max Input Power VA7,5 VA (24 V), 11 VA (230 V)Max Input Power W4 W (24 V), 4 W (230 V)
MountingRecessNominal Supply Voltage24-230 V, 50/60 Hz AC, DC
Protection ClassIII (24 V), I (230 V)Aperture for Recess Mountingø75
Temperature Range Min - Max (°C)-30...+50Suitable for Through-WiringYes
Product codeY0471W
Electrical number (FI)4281551
GTIN6438045017129
TARIC code94056180
Weight0,50 kg
Measurements38,50 × 11,50 × 9,50 cm
Body materialplastic
CE MarkYes
ColourRAL9003
Electrical Installation2 x 2,5 mm² (24 V), 3 x 2,5 mm² (230 V)
EN 60598-2-22Yes
ETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)650
IP ClassIP20
Light SourceLED
Luminous Flux (lm)280
Max Input Power VA7,5 VA (24 V), 11 VA (230 V)
Max Input Power W4 W (24 V), 4 W (230 V)
MountingRecess
Nominal Supply Voltage24-230 V, 50/60 Hz AC, DC
Protection ClassIII (24 V), I (230 V)
Aperture for Recess Mountingø75
Temperature Range Min - Max (°C)-30...+50
Suitable for Through-WiringYes

Scale Images

Scale image

Light Distribution Charts

Emergency lighting for open areas (ceiling mounting)

  • 0.5 lux table for open areas, in accordance with EN 1838; 0.5-m border zone is taken into account in the table.
  • Level of measurement 0.02 m, measurement result in emergency mode
R1 distance from wall, X axis
R2 mounting distance, X axis
R3 mounting distance, Y axis
R4 distance from wall, Y axis

Emergency lighting for open areas (ceiling mounting)

Mounting height (m)Below the light (lx)R1 (m)R2 (m)R3 (m)R4 (m)
--0.5 lx0.5 lx0.5 lx0.5 lx
2.54.35.510105.5
41.9611116
61.6611116
Emergency lighting for escape routes (ceiling mounting)

  • 1 lux table for the centre line of an escape route, in accordance with EN 1838.
  • Level of measurement 0.02 m, measurement results in emergency mode.
R1 distance from wall, X axis
R2 mounting distance, X axis
R4 distance from wall, Y axis

Emergency lighting for escape routes (ceiling mounting)

Mounting height (m)Below the light (lx)R1 (m)R2 (m)R4 (m)
--1 lx1 lx1 lx
2.54.35111
41.74141

Accessories

Product codeElectrical numberDescription
TMT3894280929Gasket ring TMT389Add to cart