Linespot II Midbay emergency light Y8853WM

Self-contained LED Emergency Exit Light with 3 h Battery and Lumi Test Self-testing (Invidually packed TWT8853WM)

The Linespot II Midbay is a surface-mounted emergency light. The luminaire’s optics are designed to provide a long and narrow light pattern that illuminates corridors and escape routes efficiently.
Thanks to the IP44 enclosure class, the Linespot II is also suitable for damp areas. The luminaire is easy and fast to install, thanks to a separate mounting base, which is also connected to the power supply.

3 h
icon-ce
EN 60598_2_22
850 °C
43
icon-LED
icon-LumiTest
220-240 V 50/60 Hz AC
icon-ProtectionClassII
9003 (Signal white)
icon-Through-wiring
Product codeY8853WMElectrical number (FI)4280973
GTIN6438045019406TARIC code94056180
Weight1,00 kgMeasurements18,50 × 18,50 × 5,20 cm
Backup (h)3 Body materialplastic
CE MarkYesColourRAL9003 (Signal white)
Electrical Installation2/3 x 2,5 mm²EN 60598-2-22Yes
ETIM classEmergency luminaire (EC001957)Glow Wire Test of Plastic Materials (°C)850
IP ClassIP43Light SourceLED
Lumi TestYesLuminous Flux (lm)240
Max Input Power VA4,5 VAMountingSurface
Mounting optionPendelNominal Supply Voltage220-240 V, 50/60 Hz AC
Protection ClassIITemperature Range Min - Max (°C)0...+35
Suitable for Through-WiringYes
Product codeY8853WM
Electrical number (FI)4280973
GTIN6438045019406
TARIC code94056180
Weight1,00 kg
Measurements18,50 × 18,50 × 5,20 cm
Backup (h)3
Body materialplastic
CE MarkYes
ColourRAL9003 (Signal white)
Electrical Installation2/3 x 2,5 mm²
EN 60598-2-22Yes
ETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)850
IP ClassIP43
Light SourceLED
Lumi TestYes
Luminous Flux (lm)240
Max Input Power VA4,5 VA
MountingSurface
Mounting optionPendel
Nominal Supply Voltage220-240 V, 50/60 Hz AC
Protection ClassII
Temperature Range Min - Max (°C)0...+35
Suitable for Through-WiringYes

Scale Images

Scale image

Light Distribution Charts

Emergency lighting for escape routes (ceiling mounting)

  • 1 lux table for the centre line of an escape route, in accordance with EN 1838.
  • Level of measurement 0.02 m, measurement results in emergency mode.
R1 distance from wall, X axis
R2 mounting distance, X axis
R4 distance from wall, Y axis

Emergency lighting for escape routes (ceiling mounting)

Mounting height (m)Below the light (lx)R1 (m)R2 (m)R4 (m)
--1 lx1 lx1 lx
2.5405111
4156.5171
667.5201
83.57211
1026.5211

How to contact our sales teams