Solid Zone Midbay emergency light TWS3692WA

Self-contained Escap Emergency light for open areas with 1 h Super Capacitor and Wireless Central Monitoring

Designed for emergency lighting in open areas, Solid Zone Midbay is an emergency light with a IP65 enclosure.
The luminaire is completely dust proof and water proof, so it is suitable for example for industrial premises and parking halls. Escap and centrally supplied luminaires supplied luminaires are also suitable for outdoor use.
The Solid luminaire uses long lasting leds as its light source.
Special attention has been paid to the design, for easy installation.

icon-AaltoControl
1 h
icon-ce
EN 1838
EN 60598_2_22
icon-Escap
850 °C
65
icon-LED
icon-LumiTest
220-240 V 50/60 Hz AC
icon-ProtectionClassII
9003
icon-Through-wiring
Product codeTWS3692WAElectrical number4282280
GTIN6438045021133TARIC code94056180
Weight1,50 kgMeasurements37,10 × 18,10 × 5,70 cm
Aalto ControlYesBackup (h)Yes
Body materialplasticCE MarkYes
ColourRAL9003Electrical Installation2/3 x 2,5 mm²
EN 1838YesEN 60598-2-22Yes
EscapYesETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)850 IP ClassIP65
Light SourceLEDLumi TestYes
Luminous Flux (lm)93 Max Input Power VA3 VA
MountingSurfaceNominal Supply Voltage220-240 V, 50/60 Hz AC
Protection ClassIITemperature Range Min - Max (°C)-25…+35
Suitable for Through-WiringYes
Product codeTWS3692WA
Electrical number4282280
GTIN6438045021133
TARIC code94056180
Weight1,50 kg
Measurements37,10 × 18,10 × 5,70 cm
Aalto ControlYes
Backup (h)Yes
Body materialplastic
CE MarkYes
ColourRAL9003
Electrical Installation2/3 x 2,5 mm²
EN 1838Yes
EN 60598-2-22Yes
EscapYes
ETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)850
IP ClassIP65
Light SourceLED
Lumi TestYes
Luminous Flux (lm)93
Max Input Power VA3 VA
MountingSurface
Nominal Supply Voltage220-240 V, 50/60 Hz AC
Protection ClassII
Temperature Range Min - Max (°C)-25…+35
Suitable for Through-WiringYes

Scale Images

Scale image

Light Distribution Charts

Emergency lighting for open areas (ceiling mounting)

  • 0.5 lux table for open areas, in accordance with EN 1838; 0.5-m border zone is taken into account in the table.
  • Level of measurement 0.02 m, measurement result in emergency mode
R1 distance from wall, X axis
R2 mounting distance, X axis
R3 mounting distance, Y axis
R4 distance from wall, Y axis

Emergency lighting for open areas (ceiling mounting)

Mounting height (m)Below the light (lx)R1 (m)R2 (m)R3 (m)R4 (m)
--0.5 lx0.5 lx0.5 lx0.5 lx
2.592662
36.526.56.52
442.5772.5
6238.58.53
813.5993.5