Trail Zone Midbay emergency light TWTC571W

24-230 V centrally supplied emergency light

Teknoware Trail is an elegant emergency light that is easy to install on a lighting track. Thanks to its unique design, it is suitable for direct mounting on common lighting track systems. The luminaire can also be mounted directly on the ceiling. Trail has a modern and streamlined appearance so it blends in with the surroundings and architecture. Trail’s wide product family and range of optics offer many options to suit a variety of applications and systems.
Trail Zone Midbay provides a broad, even pattern that illuminates open areas efficiently.

icon-ce
EN 1838
EN 60598_2_22
650 °C
20
icon-LED
24-230 V 50/60 Hz AC DC
icon-ProtectionClassIII
icon-ProtectionClassI
9003
icon-Through-wiring
Product codeTWTC571WElectrical number4244192
GTIN6438045025179TARIC code94056180
Weight0,90 kgMeasurements34,50 × 8,00 × 4,80 cm
Body materialmetalCE MarkYes
ColourRAL9003Electrical Installation2 x 2,5 mm² (24 V), 3 x 2,5 mm² (230 V)
EN 1838YesEN 60598-2-22Yes
ETIM classEmergency luminaire (EC001957)Glow Wire Test of Plastic Materials (°C)650
IP ClassIP20Light SourceLED
Luminous Flux (lm)230 Max Input Power VA7,5 VA (24 V), 11 VA (230 V)
Max Input Power W4 W (24 V), 4 W (230 V)MountingCeiling, Rail, Surface
Nominal Supply Voltage24-230 V, 50/60 Hz AC, DCProtection ClassIII (24 V), I (230 V)
Temperature Range Min - Max (°C)-30...+50Suitable for Through-WiringYes
Product codeTWTC571W
Electrical number4244192
GTIN6438045025179
TARIC code94056180
Weight0,90 kg
Measurements34,50 × 8,00 × 4,80 cm
Body materialmetal
CE MarkYes
ColourRAL9003
Electrical Installation2 x 2,5 mm² (24 V), 3 x 2,5 mm² (230 V)
EN 1838Yes
EN 60598-2-22Yes
ETIM classEmergency luminaire (EC001957)
Glow Wire Test of Plastic Materials (°C)650
IP ClassIP20
Light SourceLED
Luminous Flux (lm)230
Max Input Power VA7,5 VA (24 V), 11 VA (230 V)
Max Input Power W4 W (24 V), 4 W (230 V)
MountingCeiling, Rail, Surface
Nominal Supply Voltage24-230 V, 50/60 Hz AC, DC
Protection ClassIII (24 V), I (230 V)
Temperature Range Min - Max (°C)-30...+50
Suitable for Through-WiringYes

Scale Images

Scale image

Light Distribution Charts

Emergency lighting for open areas (ceiling mounting)

  • 0.5 lux table for open areas, in accordance with EN 1838; 0.5-m border zone is taken into account in the table.
  • Level of measurement 0.02 m, measurement result in emergency mode
R1 distance from wall, X axis
R2 mounting distance, X axis
R3 mounting distance, Y axis
R4 distance from wall, Y axis

Emergency lighting for open areas (ceiling mounting)

Mounting height (m)Below the light (lx)R1 (m)R2 (m)R3 (m)R4 (m)
--0.5 lx0.5 lx0.5 lx0.5 lx
2.52535.55.53
493.56.56.53.5
644.5884.5
82.559.59.55
101.5510105
Emergency lighting for escape routes (ceiling mounting)

  • 1 lux table for the centre line of an escape route, in accordance with EN 1838.
  • Level of measurement 0.02 m, measurement results in emergency mode.
R1 distance from wall, X axis
R2 mounting distance, X axis
R4 distance from wall, Y axis

Emergency lighting for escape routes (ceiling mounting)

Mounting height (m)Below the light (lx)R1 (m)R2 (m)R4 (m)
--1 lx1 lx1 lx
2.5252.561
49381
64491
82.54.5111
101.53.5111

Required products

Product codeElectrical numberDescription